Domicile / Produit / Porte à tourniquets / Porte Barrière des Volets / Porte de barrière à volets haute performance
Porte barrière à volets haute performance
Porte barrière à volets à grande vitesse
high-speed flap barrier
High-Performance Flap Barrier
Porte barrière à volets haute performance
Porte barrière à volets à grande vitesse
high-speed flap barrier
High-Performance Flap Barrier

Porte de barrière à volets haute performance

IM.XY.08

L’IM.XY.08 Flap Barrier Gate is a high-performance access control device designed for efficient and secure pedestrian flow management. It integrates advanced structural design, reliable safety mechanisms, and flexible identification integration capabilities, making it suitable for a wide range of scenarios such as office buildings, shopping malls, railway stations, Aéroports, et des parcs industriels.

  • icon_mark

    Channnel Width: ≤ 600 mm

  • icon_mark

    Matériel: 1.5 SGCC épaisseur en mm

  • icon_mark

    Moteur d’entraînement: Moteur à courant continu sans balais / Servo-moteur optionnel

  • icon_mark

    Capteurs: 4 paires de capteurs IR. 6 Couples optionnels

  • icon_mark

    Taille: longueur 600 *Largeur 280 *hauteur 980 mm

  • Certificat CCC
  • Certificat FCC
  • Certificat ROHS
  • Certificat ISO
  • CE certificate
TÉLÉCHARGER

Ultra-short Body

Affichage LED

6 Paires de détecteurs infrarouges

QR

High-Performance Flap Barrier Gate is a smart pedestrian access solution engineered for high-traffic environments where speed, sécurité, and user experience are essential. Designed with durable components and equipped with intelligent control systems, this gate offers reliable and efficient operation in locations such as metro stations, Immeubles de bureaux, Installations gouvernementales, Aéroports, and business parks.

Construit à partir de 1.5 SGCC épaisseur en mm, the cabinet provides excellent resistance to corrosion and wear, while the retractable flaps—typically made of acrylic or polycarbonate—ensure smooth and silent movement. The compact, modern design seamlessly integrates into both contemporary and traditional architectural settings.

This flap barrier gate supports bi-directional operation and handles 40–60 people per minute, making it ideal for peak-hour access control. It supports various identification methods, y compris les cartes RFID, Empreintes digitales, Reconnaissance faciale, Codes QR, and mobile app credentials. Integration with existing access control platforms is easy via RS485, TCP/IP, or dry contact signals.

Fonctionnalités:

  • Fast opening/closing time de <0.5 seconds per cycle
  • Anti-tailgating detection using multiple infrared sensors
  • Anti-pinch protection for user safety during passage
  • Automatic flap retraction during power failure or emergency
  • LED indicators and voice prompts for user guidance
  • Modular internal structure for easier maintenance and upgrades
  • Customizable passage width, typiquement 550–600 mm

User safety is a core priority. Multiple infrared sensors monitor passage, detect unauthorized trailing, and trigger safe flap behavior when a person or object is in the lane. In emergencies or power loss, the system activates a fail-safe open mode, allowing unrestricted passage for evacuation.

The gate is also designed with operational convenience in mind. Features like real-time status monitoring, entry/exit counting, and alarm integration help streamline access control for both users and facility managers.

With a long service life, low maintenance requirement, and premium appearance, the High-Performance Flap Barrier Gate delivers a powerful balance of performance and reliability for modern access control systems.

  • Détails du produit
  • Spécifications
  • Installation et utilisation
  • Notes
  • FAQ
Détails du produit

Caractéristiques fonctionnelles

  • Fast opening and closing time (<0.5 Secondes), ensuring high throughput in busy access points
  • Supports bi-directional pedestrian flow with configurable entry and exit logic
  • Compatible with multiple authentication methods: RFID, empreinte digitale, Reconnaissance faciale, Code QR, Identifiants mobiles
  • Equipped with anti-tailgating sensors to prevent unauthorized following
  • Infrared-based anti-pinch protection for enhanced user safety during passage
  • Flaps automatically open in case of power failure or fire alarm for emergency evacuation
  • LED indicators and optional audio prompts provide clear user guidance
  • Easily integrates with third-party access control, Billetterie, or time attendance systems
  • Construit avec 1.5 mm thickness SGCC housing and high-strength acrylic or polycarbonate flaps
  • Customizable lane width to accommodate accessibility needs (Fauteuils roulants, Poussettes, etc.)
Spécifications

Paramètres techniques

Paramètre Spécification
Flap Material Acrylique / Polycarbonate
Taille (L×W×H) 600*280*980 mm (personnalisable)
Standard Passage Width 550 mm (Optionnel: 600–900 mm)
Alimentation AC 100–240V, 50/60Hz
Tension de fonctionnement 24V DC
Type moteur Moteur sans balais à courant continu / Servomoteur (Optionnel)
Opening/Closing Time 0.3–0,6 seconde
Débit 35–60 persons/min (depending on settings)
Interface de contrôle RS485 / TCP-IP / Contact sec
Température de travail -20°C à +60°C
Operating Humidity ≤95% RH, non-condensing
Protection contre l’entrée IP54 (Optional IP65 for semi-outdoor use)
Communication Interface Wiegand 26/34, RS485, Relay Signal
Méthodes d’authentification RFID, Code QR, Biométrique (Face/Fingerprint), App
Intervention d’urgence Automatic flap opening on power failure/alarm
Mean Cycles Between Failures ≥5 millions de cycles
Noise Level < 60 Db
Environnement d’installation Intérieur / Extérieur couvert
Installation et utilisation

Étapes d’installation

Avant l’installation, ensure the site surface is level, dry, et structurellement solide. Use the provided mounting template to mark drilling points, and confirm the alignment of single or multiple lane configurations. Power and signal lines (Par exemple,, AC 220V, RS485, TCP/IP) should be laid in advance with protective conduits, ensuring proper grounding and separation from high-voltage systems.

Position the gate cabinets accurately, drill anchor holes, and secure the units using expansion bolts. Internal wiring should follow the manufacturer’s schematic diagram. Connect the motor, Carte de contrôle, Capteurs, and access control interfaces carefully. After completing all wiring, power on the system and verify correct functionality, including flap movement, Réponse des capteurs, and emergency behavior.

For multi-lane installations, synchronize communication settings and test signal coordination between devices. Calibrate flap opening time, delay settings, and direction logic through the control panel or PC software.

⚠️ Always disconnect power during installation or maintenance to avoid electrical hazards.

Utiliser

Une fois installé, the flap barrier gate offers intelligent and secure control of pedestrian flow. Users present valid credentials—such as RFID cards, biometric ID, Codes QR, or mobile access—through the integrated or external reader. Upon authentication, the flap retracts rapidly to allow passage in the configured direction.

The system supports both one-way and bi-directional flow. LED indicators and audio prompts guide users clearly, while sensors monitor tailgating, intrusion, and obstruction in real-time. If an object or person is detected during operation, the gate halts immediately and resumes only when safe.

In case of power failure or emergency alarm, the flaps automatically open to allow free passage. The system also supports integration with fire control systems for automated evacuation response.

Routine operation includes monitoring device performance, keeping sensors clean, and checking communication with access control systems. Maintenance is minimal but recommended every 3–6 months.

Notes

Before beginning installation or wiring, be sure to disconnect the power supply to prevent the risk of electric shock or damage to internal components. The device should be installed in a stable, well-ventilated environment. Avoid locations with high humidity, high temperature, corrosive substances, or strong electromagnetic interference, as these may negatively affect performance or cause long-term damage.

During operation, ensure that users pass through the gate only after valid authentication. Forcing entry or tailgating may trigger alarms or cause damage to the mechanism. If the passage is obstructed, the flap will stop or retract automatically. Do not manually push the flaps, as doing so may damage the motor or drive system.

Regular maintenance is essential to ensure stable performance. It is recommended to clean the sensors and housing periodically, check the response of access control devices, and verify that all indicators, Alarmes, and emergency functions operate as intended. Flap movement should be smooth, without abnormal noise or delay.

In the event of a malfunction, do not disassemble or attempt to repair the equipment yourself. Please contact qualified technical personnel or the manufacturer’s service team for inspection and repair. Unauthorized disassembly may void the product warranty and lead to further damage.

To ensure safety during emergencies, connect the device to the building’s fire control system where applicable. This allows automatic gate opening for rapid evacuation during fire alarms or power failure situations.

FAQ

1. What is the typical opening/closing speed of the flap gate?

The flap wings open and close in less than 0.5 Secondes, enabling fast and smooth user flow, Surtout aux heures de pointe.

2. Can the flap barrier be integrated with our existing access control system?

Oui. The gate supports RS485, TCP/IP, et interfaces de contact sec. It is compatible with most third-party systems, including RFID, biométrique, Code QR, and mobile app platforms.

3. What happens during a power failure or fire alarm?

In the event of a power outage or fire alarm trigger, the flaps automatically retract to allow free passage for evacuation, ensuring user safety.

4. Is the system safe for children and elderly users?

Oui. The gate features multiple infrared sensors and anti-pinch technology that prevent the flaps from closing when people or objects are detected in the passageway.

5. How often should the system be maintained?

Routine maintenance is recommended every 3–6 months. This includes checking the flap movement, cleaning sensors, testing access response, and ensuring all components function correctly.

Contactez-nous dès aujourd’hui

♦Haute qualité, Tourniquets à prix compétitif
♦Livraison ponctuelle, Portée mondiale
♦Devis détaillé gratuit à l’intérieur 12 Heures